| Model | FI-C20D | |||
| Type | Probe type | |||
| Attachment | — | |||
| Detection principle | Refractive index (surface light source) | |||
| Rated concentration range | Brix: 0–20% (nD: 1.32500–1.37000) | |||
| Display method | Status indicator light | |||
| Display range | Brix: 0–25% | |||
| Supported fluids | Non-corrosive aqueous solutions (such as water-soluble coolants, mold release agents, etc.)*1 | |||
| Supported fluid temperature | 0–70°C 32–158°F (no freezing) | |||
| Connection diameter | — | |||
| Rated pressure range | ||||
| Pressure resistance | ||||
| Display resolution | Brix: 0.01/0.1% (default value: 0.1)(nD: 0.00001) | |||
| Response time | 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s | |||
| Measurement accuracy | Brix: ±0.2%*2*3 (nD: ±0.0003) | |||
| Concentration unit | Brix nD*4 | |||
| Temperature measurement accuracy | ±1.0°C 1.8°F*2 | |||
| Power supply | Current consumption | 25 mA or less | ||
| Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) | ||
| Ambient temperature | –10 to +60°C 14 to +140°F (no freezing) | |||
| Relative humidity | 35–85% RH (no condensation) | |||
| Vibration resistance | 10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions | |||
| Shock resistance | 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions | |||
| Material | Liquid end materials | Sensor element: synthetic quartzBody: aluminum die-cast (nickel chrome plating) / SUS304Pipe: aluminum alloy (anodized); Gasket: FKM | ||
| Other materials | Indicator light: PPSU / TPU / PBTCable: PUR | |||
| Weight | Approx. 480 g 16.93 oz | |||
| *1 Use water as the solvent, and use materials that are soluble in water. If the particles are not water soluble, such as with slurry, the refractive index may not change.*2 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type, condition and temperature of the fluid used by the customer, as well as other factors.*3 This is the value obtained when sucrose solution is used in a constant 20°C 68°F environment, and absolute error and repeatability is taken into account.*4 When using solutions other than sucrose solutions, concentration can be adjusted via span adjustment. | ||||